CVE-2026-4641
7.4HighPublished Nov 27, 2026 · NVD status: Received · AI triage by gemini-3.1-flash-lite
High
0CVSS v3.110
- Attack vector
- Local
- Complexity
- High
- Privileges
- None
- User action
- None
- Impact
- Full C/I/A compromise
- Weakness
- CWE-863
What an attacker gets
Local attackers can bypass authorization controls to gain full access to the relay. This requires physical or local network access to the device.
Root cause
The device fails to properly enforce authorization checks for certain operations.
Affected versions
Various versions across REX610, RE_611, RBX615, REF615, RER615, REC615, REX615, 615 series, RER620, 620 series, REX640, and SMU615.
CVSS v3.1 · CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H
Fix & remediation
Upgrade to the firmware version specified in ABB advisory 2NGA002995. Restrict physical and network access to the management interfaces of these relays.
AI-suggested. Run it in staging first and check it against the vendor advisory. Why?
NVD description
Incorrect Authorization vulnerability in ABB Relion Protection Relays REX610, ABB Relion Protection Relays RE_611 IEC/CN, ABB Relion Protection Relays RBX615, ABB Relion Protection Relays REF615 ANSI, ABB Relion Protection Relays REF615R ANSI, ABB Relion Protection Relays RER615, ABB Relion Protection Relays REC615, ABB Relion Protection Relays REX615, ABB Relion Protection Relays 615 series IEC, ABB Relion Protection Relays 615 series CN, ABB Relion Protection Relays 615 series ANSI, ABB Relion Protection Relays RER620 ANSI, ABB Relion Protection Relays 620 series ANSI, ABB Relion Protection Relays 620 series IEC/CN, ABB Relion Protection Relays REX640, and ABB Substation Merging Unit SMU615. This issue affects Relion Protection Relays REX610: 1.0, 1.1, and 1.2; Relion Protection Relays RE_611 IEC/CN: 1.0 and 2.0; Relion Protection Relays RBX615: 1.0 and 2.0; Relion Protection Relays REF615 ANSI: 4.1; Relion Protection Relays REF615R ANSI: 4.0 and 4.0 FP1; Relion Protection Relays RER615: 1.0, 1.1, and 2.0; Relion Protection Relays REC615: 1.0, 1.1, 2.0, and 3.0; Relion Protection Relays REX615: PCL1 (6.0), PCL2 (SW 6.1), and PCL3 (SW 6.2); Relion Protection Relays 615 series IEC: 3.1, 4.0, 4.0 FP1, 5.0, and 5.0 FP1; Relion Protection Relays 615 series CN: 3.1, 4.1, and 5.0 FP1; Relion Protection Relays 615 series ANSI: 4.0, 4.0 FP1, 4.0 FP2, and 5.0 FP1; Relion Protection Relays RER620 ANSI: 1.1, 1.2, and 1.3; Relion Protection Relays 620 series ANSI: 2.0 and 2.0 FP1; Relion Protection Relays 620 series IEC/CN: 2.0 and 2.0 FP1; Relion Protection Relays REX640: PCL1 (1.0), PCL1 (1.1), PCL1 (1.2), PCL1 (1.3), PCL1 (2.0), PCL2 (1.0), PCL2 (1.1), PCL2 (1.2), PCL2 (1.3), PCL2 (2.0), PCL3 (1.0), PCL3 (1.1), PCL3 (1.2), PCL3 (1.3), PCL3 (2.0), PCL4 (1.0), PCL4 (1.1), PCL4 (1.2), PCL4 (1.3), PCL4 (2.0), PCL5 (1.0), PCL5 (1.1), PCL5 (1.2), PCL5 (1.3), PCL5 (2.0), PCL6 (SW 6.1), and PCL7 (SW 6.2); Substation Merging Unit SMU615: 1.0.
References
Related Critical / High CVEs
More fully triaged vulnerabilities you may want to check next.
- CVE-2026-1381637.8HighAttackers can execute arbitrary code or crash the application by providing a malicious backup file. This requires a user to load a crafted backup file into Gammu.
- CVE-2026-1381627.0HighAttackers can execute arbitrary code or crash the application by providing a crafted backup file. This requires a user to perform a restore or addnew operation on an attached Alcatel phone.
- CVE-2026-1381617.8HighAttackers can achieve code execution by providing a crafted backup file with an overlong MD5 value. This requires a user to process a malicious file using convertbackup or restore.
- CVE-2026-1381607.8HighAttackers can execute arbitrary code or crash the application by providing a malicious backup file. This requires a user to trigger a restore or backup process with a crafted file.
- CVE-2026-1381597.5HighRemote attackers can execute arbitrary code or crash the application by sending a response body larger than 2 GB. This requires a user to browse to an attacker-controlled HTTP, FTP, or gopher server.
- CVE-2026-1381548.6HighAttackers can execute arbitrary code on your machine as the current user. This requires a user to subscribe to a malicious Steam Workshop mod.