CVE-2026-126978
8.8HighPublished 18 Nov 2026 · NVD status: Received · AI triage by gemini-3.1-flash-lite
High
0CVSS v3.010
- Attack vector
- Adjacent network
- Complexity
- Low
- Privileges
- None
- User action
- None
- Impact
- Full C/I/A compromise
- Weakness
- CWE-122
What an attacker gets
Network-adjacent attackers can execute arbitrary code on the Philips Hue Bridge without authentication. This allows full control over the device via the HomeKit Accessory Protocol.
Root cause
The hap_pair_setup_handler fails to validate the length of user-supplied data before copying it into a fixed-length heap buffer.
Affected versions
Versions not listed — check the vendor advisory.
CVSS v3.0 · CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Fix & remediation
Check the Philips Hue support portal for firmware updates. Until patched, block inbound traffic to TCP port 8080 on the bridge from untrusted network segments.
AI-suggested. Run it in staging first and check it against the vendor advisory. Why?
NVD description
Philips Hue Bridge hap_pair_setup_handler Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability. The specific flaw exists within the HomeKit Accessory Protocol service, which listens on TCP port 8080 by default. When parsing pairing requests, the process does not properly validate the length of user-supplied data prior to copying it to a fixed-length, heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-28434.