CVE-2026-126553

9.3Critical

Published 17 Nov 2026 · NVD status: Received · AI triage by gemini-3.1-flash-lite

9.3CVSS

Critical

0CVSS v4.010

Attack vector
Network
Complexity
Low
Privileges
None
User action
None
Impact
Full C/I/A compromise
Weakness
CWE-502

What an attacker gets

Unauthenticated attackers can achieve remote code execution on your WCC server via object injection. This requires network access to the WCC web interface.

Root cause

The application insecurely deserializes untrusted data provided by users.

Affected versions

Broadcom AutoSys Workload Automation (WCC modules) versions 12.1 through 24.0.01.

CVSS v4.0 · CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Fix & remediation

Upgrade to AutoSys Workload Automation 24.0.02 or later. If you cannot patch immediately, restrict network access to the WCC web interface to trusted management subnets only.

AI-suggested. Run it in staging first and check it against the vendor advisory. Why?

NVD description

Deserialization of Untrusted Data vulnerability in Broadcom AutoSys Workload Automation (Workload Control Center (WCC) modules) on Windows, Linux allows Object Injection.This issue affects AutoSys Workload Automation: from 12.1 through 24.0.01.

References

Source: nvd.nist.gov/vuln/detail/CVE-2026-126553