CVE-2026-118498

7.5High

Published 17 Nov 2026 · NVD status: Received · AI triage by gemini-3.1-flash-lite

7.5CVSS

High

0CVSS v3.110

Attack vector
Network
Complexity
High
Privileges
None
User action
Required
Impact
Full C/I/A compromise
Weakness
CWE-22

What an attacker gets

Unauthenticated attackers can achieve arbitrary code execution with user privileges. This requires a man-in-the-middle attack or tricking a user into connecting to a malicious Automation Server.

Root cause

The CODESYS Automation Server Connector fails to sanitize file names, allowing path traversal during file write operations.

Affected versions

Versions not listed — check the vendor advisory at https://www.certvde.com/en/advisories/VDE-2026-146/.

CVSS v3.1 · CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H

Fix & remediation

Update to the latest version provided by the vendor. Until patched, ensure all connections to Automation Servers are restricted to trusted, encrypted networks and verify server identity.

AI-suggested. Run it in staging first and check it against the vendor advisory. Why?

NVD description

The CODESYS Automation Server Connector uses server-supplied file names without sufficient path traversal checks. An unauthenticated remote attacker controlling a malicious Automation Server and tricking a user to trust it, or performing a man-in-the-middle attack on a trusted communication channel, can exploit this vulnerability to write attacker-controlled files to arbitrary locations on the engineering workstation and subsequently achieve arbitrary code execution with user privileges.

References

Source: nvd.nist.gov/vuln/detail/CVE-2026-118498