CVE-2026-101451
8.7HighPublished 20 Oct 2026 · NVD status: Awaiting Analysis · AI triage by gemini-3.1-flash-lite
High
0CVSS v3.110
- Attack vector
- Network
- Complexity
- Low
- Privileges
- Low
- User action
- Required
- Impact
- High impact on confidentiality, integrity
- Weakness
- —
What an attacker gets
Authenticated attackers can modify or steal critical data by tricking a user into clicking a malicious link. This requires network access and a user to interact with the crafted request.
Root cause
The Siebel Life Sciences Web UI fails to properly sanitize input, allowing for cross-site scripting or similar injection attacks.
Affected versions
Oracle Siebel CRM Life Sciences versions 17.0 through 26.9.
CVSS v3.1 · CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:N
Fix & remediation
Upgrade to the latest version specified in the October 2026 Oracle Critical Patch Update. If you cannot patch immediately, restrict network access to the Siebel Web UI to trusted internal networks only.
AI-suggested. Run it in staging first and check it against the vendor advisory. Why?
NVD description
Vulnerability in the Siebel Life Sciences product of Oracle Siebel CRM (component: Web UI). Supported versions that are affected are 17.0-26.9. Easily exploitable vulnerability allows low privileged attacker with network access via HTTP to compromise Siebel Life Sciences. Successful attacks require human interaction from a person other than the attacker and while the vulnerability is in Siebel Life Sciences, attacks may significantly impact additional products (scope change). Successful attacks of this vulnerability can result in unauthorized creation, deletion or modification access to critical data or all Siebel Life Sciences accessible data as well as unauthorized access to critical data or complete access to all Siebel Life Sciences accessible data. CVSS 3.1 Base Score 8.7 (Confidentiality and Integrity impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:N).